Operations Manual
Page 26
CAUTION
Follow established standing operating procedures at all times, and use
the supplied test piece to confirm that the detector registers a correct
signal before and after every use. An area that has just been checked
with the F1A4 detector should not be considered safe until the detector
has been rechecked with the test piece.
a. Ensure that the detector is emitting the correct threshold tone. If in
doubt, perform Noise Cancel or Audio Reset procedure.
b. Make sure your hands and wrists are free of any metallic objects.
c. Place the test piece with the end with the hole lightly against the
centre of the bottom of the coil.
d. Confirm that a distinct signal is registered as the test piece is
moved in the directions shown in Figure 12.
P0263-B
Figure 12 - Using the Test Piece